TOF and WC detector test with cosmic ray
TOF detector test was performed at 3F experimental room in Kyoto University.
The purpose of the test experiment is to see:
- time resolution,
- the speed of light in scintillator,
- the light attenuation in scintillator,
- etc.
Later, water Cherenkov detector was also installed to see
its performance for cosmic ray.
FIG1: Experimental setup of TOF detector test.
[.png]
[.bmp]
[.ai]
[.pdf]
FIG2: A photograph of the experimental setup.
CAD drawing
Experimental setup
(.dwg) [165 kB]
Notes
DAQ
DAQ source: camac_sample.tar [0.3 MB]
Data
- Analysis machine: sts@172.1.16.169:~/TOFtest2014/data/*.dat
- DAQ machine: tof@172.1.16.173:~/camac/data/*.dat
- Local:
NOTES about data stream:
- (run1-run45) ADC1 ADC2 ADC3 ADC4 TDC1 TDC2 TDC3 TDC4
- (run46-run93) ADC1 ADC2 ADC3 ADC4 TDC1 TDC2 TDC3 TDC4 NTDC1 NTDC2 NADC1 NADC2*1
- (run94-run113) ADC1 ADC2 ADC3 ADC4 TDC1 TDC2 TDC3 TDC4 NTDC1 NTDC2 NADC1 NADC2 ADC5 TDC5
- (run114-run183) ADC1 ADC2 ADC3 ADC4 TDC1 TDC2 TDC3 TDC4 NTDC1 NTDC2 NADC1 NADC2 ADC5 TDC5 WADC1 WADC2 WADC3*2
- (run184-) ADC1 ADC2 ADC3 ADC4 TDC1 TDC2 TDC3 TDC4 NTDC1 NTDC2 NADC1 NADC2 ADC5 TDC5
WADC1 WADC2 WADC3 WTDC1 WTDC2 WTDC3*3
*1 ADCs and TDCs of Noritake's detector which was put on the TOF detector (see FIG2).
*2 ADCs of water Cherenkov detector.
*3 TDCs of water Cherenkov detector.
Analysis
Reports
- Toshi's presentation file of S-2S meeting on 2014/10/16
→
pdf file :
Rough analysis to obtain time resolution of E05 TOF detector.
- Toshi's presentation file of S-2S meeting on 2014/10/28
→
pdf file :
Rough analysis for WC N.P.E / Experimental setup
- pptx file on 2014/10/31
→
pdf file :
Speed of Light in plastic scintillator (E05 TOF detector).
- pptx file on 2014/11/04
→
pdf file :
WC N.P.E. analysis
- pptx file made on 2014/11/11
→
pdf file :
WC N.P.E. analysis, Effective speed of light in E05 TOF detector
- pptx file on 2014/12/03
→
pdf file :
Performace of trigger counters for WC window test.
- pptx file on 2014/12/26
→
pdf file :
Presentation file for K1.8 meeting (about water Cherenkov detector test).
- pptx file on 2015/01/21
→
pdf file :
WC NPE test with cosmic ray (PMT individual difference, Reproducibility, Grease difference)
- pptx file on 2015/03/18
→
pdf file :
WC NPE test with cosmic ray (PMT individual difference, Reproducibility, Grease difference
)UPDATED
Pictures
- 1
(TOF)
- 2
(TOF)
- 3
(TOF + small scintillator / Assembling of prototype water Cherenkov detector)
- 4
(TOF + small scintillator / Assembling of prototype water Cherenkov detector)
- 5
(TOF + small scintillator + prototype water Cherenkov detector)
- 6
(TOF + small scintillator + prototype water Cherenkov detector)
- 7
(Small scintillator + prototype water Cherenkov detector)
- 8